Sequential Registration with two or more Device Adapter UNIStim endpoints feature operation

Last Updated : Jun 04, 2019 |
Prolog information
For example, a user has 1140 at the desk, a 2050 soft client on the computer, and a 96x1 in the lab. The user goes to the lab, and then goes home and registers by using the computer. The next day the user goes to the office and uses the 1140.
The user’s identity is extension 2355777, which uses node 1050 and TN 32-0-6-1.
  1. The user is registered at 1140.
  2. The user goes to the lab. The user logs in with the 96x1 in the lab as 2355777.
    1. The user can log in. The user experience and set display is similar to a 96X1 station.
    2. When Session Manager terminates the 1140 SIP registration, the 1140 displays the following messages:
      ADDITIONAL INFORMATION:
      Registration is on hold.
      Press RESET to continue.
    3. A Reset soft key is displayed at the 1140.
    4. The 96x1 can place and receive calls.
  3. User goes home and starts 2050.
    1. The 2050 soft client offers TN 32-0-6-1 and node 1050 as the station.
    2. Session Manager terminates the SIP registration of the 96x1. The user is logged out.
    3. The 2050 can place and receive calls.
  4. User goes to the office the next day and switches to 1140.
    1. The user presses the Reset soft key on the 1140.
      ADDITIONAL INFORMATION:
      • The user does not shut down the 2050.
        1. When Session Manager terminates the SIP registration, the 2050 displays the following messages:
          Registration is on hold.
          Press RESET to continue.
        2. The 2050 displays a Reset soft key.
      • The user shuts down the 2050.
        Because the 2050 is shut down, the 2050 attempts to re-register only when the user starts it again. As this is a deliberate user action, it is acceptable.
    2. The 1140 can place and receive calls.