Assigning a maximum precedence level

Last Updated : Dec 28, 2016 |

About this task

Maximum precedence levels are assigned to Classes of Restriction (COR).

Procedure

  1. Enter change cor n, where n is the number of a specific COR.
  2. Click Next until you see the Maximum Precedence Level and MLPP Service Domain fields.
  3. In the Maximum Precedence Level field, type one of the following values:
    • fo (Flash Override)

    • fl (Flash)

    • im (Immediate)

    • pr (Priority)

    • ro (Routine, the default value)

  4. In the MLPP Service Domain field, type a number from 0 to 16777215.

    This number defines the service domain for users and trunks to which this particular COR is assigned. The system uses the service domain to create a group of MLPP users or facilities, within which precedence calls can be made.

  5. Press Enter to save your changes.