Enter change station n, where n is the extension of the user for whom you want to activate an off-premises station.
In the Off-Premises Station field, perform the following actions:
If the telephone associated with this Station screen is not located in the same building as the server, type y.
If you type y, you must administer the R Balance Network field on the Station screen.
If the telephone associated with this Station screen is located in the same building as the server, type n.
In the R Balance Network field, perform one of the following actions.
Type y to select the R Balance Capacitor network. Type y in all other cases, except for the following cases:
Type n:
To select the standard resistor capacitor network
When the station port circuit is connected to the terminal equipment. Terminal equipment includes, for example, SLC carriers or impedance compensators. These are optioned for 600-ohm input impedance and the distance between the server and the equipment is less than 3,000 feet (914.4 meters).
You must complete the R Balance Network field if the Off-Premises Station field on the Station screen is set to y.