Setting up Security Violation Notification

Last Updated : Oct 04, 2016 |

Procedure

  1. Enter change system-parameters security.
  2. In the SVN Login Violation Notification Enabled field, type y.

    This action sets Security Violation Notification login violation notification.

    Note:

    If you are not using Security Violation Notification for logins, type n in the SVN Login Violation Notification Enabled field and go to Step 11.

  3. In the Originating Extension field, type 3040.

    This becomes the telephone extension for the purpose of originating and identifying SVN referral calls for login security violations.

  4. In the Referral Destination field, type attd to send all calls to the attendant.

    This is the extension of the telephone that receives the referral call when a security violation occurs.

  5. In the Login Threshold field, type 3.

    This is the minimum number of login attempts that are permitted before a referral call is made. More than 3 attempts causes a security violation notification.

  6. In the Time Interval field, type 0:03.

    This the time interval in which the threshold, or number of violations, must occur.

  7. Select Enter to save your changes.
  8. (Optional) Enter change login nnnn, where nnnn is your login ID.
  9. (Optional) In the Disable Following A Security Violation field, type y.

    This disables a login following detection of a login security violation for the login you are administering.

  10. Select Enter to save your changes.
    Note:

    If you are not using Remote Access, go to Step 14.

  11. (Optional) Enter change remote-access.
  12. (Optional) In the Disable Following A Security Violation field, type y.

    This disables remote access following detection of a remote access security violation.

  13. (Optional) Select Enter to save your changes.
  14. Enter change station n, where n is the station that you want to assign to the notification halt button.
  15. Click Next until you see the Button Assignments area.
  16. In the Button Assignments area, type one of the following values:
    • asvn-halt - The Authorization Code Security Violation Notification call is activated when an authorization code security violation is detected. This applies only if you are using authorization codes.

    • lsvn-halt - The Login Security Violation Notification call is activated a referral call when a login security violation is detected.

    • rsvn-halt - The Remote Access Barrier Code Security Violation Notification call is activated as a call referral. This applies only if you are using Remote Access barrier codes.

    • ssvn-halt - The Station Code Security Violation Notification call is activated when a station code security violation is detected. This applies only if you are using station codes.

      Note:

      Any of the above four security violations causes the system to place a notification call to the designated telephone. The call continues to ring until answered. To stop notification of any further violations, press the button associated with the type of violation.

  17. Select Enter to save your changes.