Enabling Remote Access

Last Updated : Jun 08, 2016 |

Procedure

  1. Enter change remote-access.
  2. In the Authorization Code Required field, perform one of the following actions:
    • If you want a user to enter an authorization code to use Remote Access, type y.

    • If you do not want a user to enter an authorization code when the user uses Remote Access, type n.

      The Calls Used field is a display-only field that shows the number of calls that are placed with the corresponding barrier code. The system increments this field whenever a barrier code is successfully used to access the Remote Access feature.

  3. In the Barrier Code field, perform one of the following actions:
    • Type a barrier code.

      The number that you type in the Barrier Code Length field determines the number of digits that you type in this field.

    • If the Barrier Code Length field is blank, you must type none in the first Barrier Code field.

      You can assign 10 barrier codes to your system. You cannot assign duplicate barrier codes.

  4. In the Barrier Code Length field, type the length of the barrier codes that you want to use in your system.

    Valid entries are the numbers 4 through 7. You can also leave this field blank.

  5. In the COR field, type the COR number that is associated with the barrier code.

    The barrier code defines the call restriction features.

  6. In the COS field, type the COS number that is associated with the barrier code.

    The barrier code defines access permissions for Call Processing features. Valid entries are the numbers 0 to 15.

  7. In the Disable Following a Security Violation field, perform one of the following actions:
    • If you want the system to disable the Remote Access feature when the system detects a remote access security violation, type y.

    • If you do not want the system to disable the Remote Access feature when the system detects a remote access security violation, type n.

    The system displays the Disable Following a Security Violation field when the SVN Authorization Code Violation Notification Enabled field on the Security-Related System Parameters screen is set to y.

  8. In the Expiration Date field, type the date that you want the barrier code to expire.

    You must type a date that is greater than the current date. You can also leave the field blank.

    If you assign an expiration date, the system displays a warning message on the System Copyright screen 7 days before the expiration date of the barrier code. If you want to extend the expiration date, change the date in this field.

  9. In the No. of Calls field, type the number of times that users can use the barrier code for Remote Access.

    Valid entries are the numbers 1 to 9999.

  10. In the Permanently Disable field, type n.
  11. In the Remote Access Dial Tone field, perform one of the following actions:
    • If you want the system to provide a Remote Access dial tone prompt, type y.

    • If you do not want the system to provide a Remote Access dial tone prompt, type n.

    Security alert:

    To maintain system security, Avaya recommends that you set this field to n.

    The system displays this field only when the Authorization Code Required field is set to y.

  12. In the Remote Access Extension field, perform one of the following actions:
    • If no barrier codes exist, leave the field blank.

    • If barrier codes exist, type the Remote Access extension.

      The remote access extension is used like a DID extension. Only one DID extension can be assigned as the Remote Access extension. Calls to the Remote Access extension are treated the same as calls on the remote access trunk.

  13. In the TN field, type the Tenant Partition number.

    Valid entries are the numbers 1 to 100.

  14. Select Enter to save your changes.